Sealing for the trenchless installation, setSealing for the trenchless installation, setSealing for the trenchless installation, setSealing for the trenchless installation, setSealing for the trenchless installation, setSealing for the trenchless installation, set

6871 Sealing for the trenchless installation, set

Article No. ø PEAGø D
(mm)
L
(mm)
C
(mm)
ø KB N
(mm)
weight
(kg)
Availability watchlist
6871025032 o 32/40 1"-5/4" 170 105 90-130 90 2.000 ex warehouse
6871040000 o 50 1 1/2" 200 105 90-130 120 2.000 ex warehouse
6871050000 o 63 2" 200 105 90-130 120 2.000 ex warehouse
6871025132 x 32/40 1"-5/4" 170 105 90-130 90 2.000 ex warehouse
6871040100 x 50 1 1/2" 200 105 90-130 120 2.000 ex warehouse
6871050100 x 63 2" 200 105 90-130 120 2.000 ex warehouse
DN
watchlist
6871025032
o
ø PE32/40
AG1"-5/4"
ø D170 mm
L105 mm
C90-130 mm
ø KB N90 mm
weight2.000 kg
Availabilityex warehouse
6871040000
o
ø PE50
AG1 1/2"
ø D200 mm
L105 mm
C90-130 mm
ø KB N120 mm
weight2.000 kg
Availabilityex warehouse
6871050000
o
ø PE63
AG2"
ø D200 mm
L105 mm
C90-130 mm
ø KB N120 mm
weight2.000 kg
Availabilityex warehouse
6871025132
x
ø PE32/40
AG1"-5/4"
ø D170 mm
L105 mm
C90-130 mm
ø KB N90 mm
weight2.000 kg
Availabilityex warehouse
6871040100
x
ø PE50
AG1 1/2"
ø D200 mm
L105 mm
C90-130 mm
ø KB N120 mm
weight2.000 kg
Availabilityex warehouse
6871050100
x
ø PE63
AG2"
ø D200 mm
L105 mm
C90-130 mm
ø KB N120 mm
weight2.000 kg
Availabilityex warehouse
  • x = Cover plate divided
  • o = Cover plate fixed

Application

  • For the professional installation of wall ducts that are only accessible from the inside. (Trenchless pipeline construction)

Characteristics

  • Simple, inexpensive and safe installation of the wall duct that is gas- and water-tight.
  • Professional sealing (grouting) of the wall duct gas and watertight
  • Clean conical exterior wall/cover without any danger of water accumulation
  • Turning and tensile forces are transmitted to the masonry
  • The set consists of a watertight curtain (rubber), spacer, internal cover plate and fastening materials.

Installation and assembly

  • Prepare core drilling for mounting the wall duct. The outside wall must be clean in the region of the watertight curtain.
  • Push the wall duct with mounted watertight curtain (note the wall thickness) into the core drilling, pre-tension grouting device tool from inside and pour out the grout (Beto Fix). After the curing time, remove the grouting device tool and mount the cover plate.
  • After the curing time, remove the grouting device tool and mount the cover plate.
  • Feedthrough of copper wire/ earthing strip is possible

Caution

  • W = the long wall duct must be used for a wall thickness greater than 250 mm.
more