Sealing for the trenchless installation, setSealing for the trenchless installation, setSealing for the trenchless installation, setSealing for the trenchless installation, set

68710 Sealing for the trenchless installation, set

Article No. ø PEAGø D
(mm)
L
(mm)
C
(mm)
ø KB N
(mm)
weight
(kg)
Availability watchlist
6871025005 o 32 1" 170 105 90-130 90 2.000 ex warehouse
6871032045 o 40/50 5/4"-1 1/2" 200 105 90-130 120 2.000 ex warehouse
6871050005 o 63 2" 200 105 90-130 120 2.000 ex warehouse
6871025105 x 32 1" 170 105 90-130 90 2.000 ex warehouse
6871032145 x 40/50 5/4"-1 1/2" 200 105 90-130 120 2.000 ex warehouse
6871050105 x 63 2" 200 105 90-130 120 2.000 ex warehouse
DN
watchlist
6871025005
o
ø PE32
AG1"
ø D170 mm
L105 mm
C90-130 mm
ø KB N90 mm
weight2.000 kg
Availabilityex warehouse
6871032045
o
ø PE40/50
AG5/4"-1 1/2"
ø D200 mm
L105 mm
C90-130 mm
ø KB N120 mm
weight2.000 kg
Availabilityex warehouse
6871050005
o
ø PE63
AG2"
ø D200 mm
L105 mm
C90-130 mm
ø KB N120 mm
weight2.000 kg
Availabilityex warehouse
6871025105
x
ø PE32
AG1"
ø D170 mm
L105 mm
C90-130 mm
ø KB N90 mm
weight2.000 kg
Availabilityex warehouse
6871032145
x
ø PE40/50
AG5/4"-1 1/2"
ø D200 mm
L105 mm
C90-130 mm
ø KB N120 mm
weight2.000 kg
Availabilityex warehouse
6871050105
x
ø PE63
AG2"
ø D200 mm
L105 mm
C90-130 mm
ø KB N120 mm
weight2.000 kg
Availabilityex warehouse
  • o = Cover plate fixed
  • x = Cover plate divided

Application

  • For the professional installation of wall ducts that are only accessible from the inside. (Trenchless pipeline construction)

Characteristics

  • Simple, inexpensive and safe installation of the wall duct that is gas- and water-tight.
  • Professional sealing (grouting) of the wall duct gas and watertight
  • Clean conical exterior wall/cover without any danger of water accumulation
  • Turning and tensile forces are transmitted to the masonry
  • The set consists of a watertight curtain (rubber), spacer, internal cover plate and fastening materials.

Installation and assembly

  • Prepare core drilling for mounting the wall duct. The outside wall must be clean in the region of the watertight curtain.
  • Push the wall duct with mounted watertight curtain (note the wall thickness) into the core drilling, pre-tension grouting device tool from inside and pour out the grout (Beto Fix). After the curing time, remove the grouting device tool and mount the cover plate.
  • After the curing time, remove the grouting device tool and mount the cover plate.
  • Feedthrough of copper wire/ earthing strip is possible

Caution

  • W = the long wall duct must be used for a wall thickness greater than 250 mm.
more