Article No. | ø PE | AG | ø D (mm) | L (mm) | C (mm) | ø KB N (mm) | weight (kg) | Availability | watchlist | |
---|---|---|---|---|---|---|---|---|---|---|
6871025005 | o | 32 | 1" | 170 | 105 | 90-130 | 90 | 2.000 | ex warehouse | |
6871032045 | o | 40/50 | 5/4"-1 1/2" | 200 | 105 | 90-130 | 120 | 2.000 | ex warehouse | |
6871050005 | o | 63 | 2" | 200 | 105 | 90-130 | 120 | 2.000 | ex warehouse | |
6871025105 | x | 32 | 1" | 170 | 105 | 90-130 | 90 | 2.000 | ex warehouse | |
6871032145 | x | 40/50 | 5/4"-1 1/2" | 200 | 105 | 90-130 | 120 | 2.000 | ex warehouse | |
6871050105 | x | 63 | 2" | 200 | 105 | 90-130 | 120 | 2.000 | ex warehouse |
DN
watchlist
6871025005 | ||
o | ||
ø PE | 32 | |
AG | 1" | |
ø D | 170 mm | |
L | 105 mm | |
C | 90-130 mm | |
ø KB N | 90 mm | |
weight | 2.000 kg | |
Availability | ex warehouse | |
6871032045 | ||
o | ||
ø PE | 40/50 | |
AG | 5/4"-1 1/2" | |
ø D | 200 mm | |
L | 105 mm | |
C | 90-130 mm | |
ø KB N | 120 mm | |
weight | 2.000 kg | |
Availability | ex warehouse | |
6871050005 | ||
o | ||
ø PE | 63 | |
AG | 2" | |
ø D | 200 mm | |
L | 105 mm | |
C | 90-130 mm | |
ø KB N | 120 mm | |
weight | 2.000 kg | |
Availability | ex warehouse | |
6871025105 | ||
x | ||
ø PE | 32 | |
AG | 1" | |
ø D | 170 mm | |
L | 105 mm | |
C | 90-130 mm | |
ø KB N | 90 mm | |
weight | 2.000 kg | |
Availability | ex warehouse | |
6871032145 | ||
x | ||
ø PE | 40/50 | |
AG | 5/4"-1 1/2" | |
ø D | 200 mm | |
L | 105 mm | |
C | 90-130 mm | |
ø KB N | 120 mm | |
weight | 2.000 kg | |
Availability | ex warehouse | |
6871050105 | ||
x | ||
ø PE | 63 | |
AG | 2" | |
ø D | 200 mm | |
L | 105 mm | |
C | 90-130 mm | |
ø KB N | 120 mm | |
weight | 2.000 kg | |
Availability | ex warehouse | |
Application
- For the professional installation of wall ducts that are only accessible from the inside. (Trenchless pipeline construction)
Characteristics
- Simple, inexpensive and safe installation of the wall duct that is gas- and water-tight.
- Professional sealing (grouting) of the wall duct gas and watertight
- Clean conical exterior wall/cover without any danger of water accumulation
- Turning and tensile forces are transmitted to the masonry
- The set consists of a watertight curtain (rubber), spacer, internal cover plate and fastening materials.
Installation and assembly
- Prepare core drilling for mounting the wall duct. The outside wall must be clean in the region of the watertight curtain.
- Push the wall duct with mounted watertight curtain (note the wall thickness) into the core drilling, pre-tension grouting device tool from inside and pour out the grout (Beto Fix). After the curing time, remove the grouting device tool and mount the cover plate.
- After the curing time, remove the grouting device tool and mount the cover plate.
- Feedthrough of copper wire/ earthing strip is possible
Caution
- W = the long wall duct must be used for a wall thickness greater than 250 mm.
more