Aeration/ventilation valve for waste water, PN 16Aeration/ventilation valve for waste water, PN 16Aeration/ventilation valve for waste water, PN 16Aeration/ventilation valve for waste water, PN 16

9881 Aeration/ventilation valve for waste water, PN 16

Article No. DNPN
(bar)
B
(mm)
B1
(mm)
H
(mm)
H1
(mm)
weight
(kg)
Availability watchlist
9881050000 50 10/16 270 100 615 180 20.000 ex warehouse
9881080000 80 10/16 270 100 615 180 21.000 ex warehouse
9881100000 100 10/16 270 100 615 180 23.000 ex warehouse
9881150000 150 10/16 270 100 615 180 25.000 on demand
9881200000 200 10 270 100 615 180 28.000 on demand
DN
watchlist
9881050000 50
PN10/16 bar
B270 mm
B1100 mm
H615 mm
H1180 mm
weight20.000 kg
Availabilityex warehouse
9881080000 80
PN10/16 bar
B270 mm
B1100 mm
H615 mm
H1180 mm
weight21.000 kg
Availabilityex warehouse
9881100000 100
PN10/16 bar
B270 mm
B1100 mm
H615 mm
H1180 mm
weight23.000 kg
Availabilityex warehouse
9881150000 150
PN10/16 bar
B270 mm
B1100 mm
H615 mm
H1180 mm
weight25.000 kg
Availabilityon demand
9881200000 200
PN10 bar
B270 mm
B1100 mm
H615 mm
H1180 mm
weight28.000 kg
Availabilityon demand

Mode of operation

  • Infinite automatic aeration and ventilation valve for waste water, untreated water and drinking water. The infinite variable aeration and ventilation is done via a mesh seat with a rolling membrane system. The seal seat does not come into contact with the waste water, so it prevent the seat from getting blocked up and thus provides high operational safety.

Characteristics

  • Self-acting
  • All parts are corrosion resistant
  • Efficient purging during maintenance work.
  • On request, the aeration and ventilation valve is also available in the colour blue or in the material INOX.

Material

  • Housing, cover and flange: ST 37 with EWS-coating (Inox on request)
  • Diaphragm holder (mesh): POM
  • Membrane: EPDM
  • Float ball: POM
  • Outlet bend d 50: PE 100

Performance data

  • Opening cross-section: 480 mm²
  • Ventilation capacity: 440 m³/h
  • Aeration capacity: 427 m³/h
  • Operating range: 0 to 16 bar

Medium

  • Domestic waste water, drinking water

Medium temperature

  • max. 40 °C

Test pressure

  • Housing: 24 bar
more