1795 On/Off valve for electrical remote control stepwise working - closed without current

Article No. DNPN
(bar)
L
(mm)
weight
(kg)
Availability watchlist
1795007000 1 1/2" 16 210 10.000 on demand
1795008000 2" 16 210 13.000 on demand
1795040000 40 16 200 11.500 on demand
1795050000 50 16 230 11.500 on demand
1795065000 65 16 290 17.000 on demand
1795080000 80 16 310 23.000 on demand
1795100000 100 16 350 32.000 on demand
1795125000 125 16 400 48.000 on demand
1795150000 150 16 480 76.000 on demand
1795200000 200 10 600 118.000 on demand
1795200016 200 16 600 105.000 on demand
1795250000 250 10/16 730 243.000 on demand
1795300000 300 10/16 850 354.000 on demand
DN
watchlist
1795007000 1 1/2"
PN16 bar
L210 mm
weight10.000 kg
Availabilityon demand
1795008000 2"
PN16 bar
L210 mm
weight13.000 kg
Availabilityon demand
1795040000 40
PN16 bar
L200 mm
weight11.500 kg
Availabilityon demand
1795050000 50
PN16 bar
L230 mm
weight11.500 kg
Availabilityon demand
1795065000 65
PN16 bar
L290 mm
weight17.000 kg
Availabilityon demand
1795080000 80
PN16 bar
L310 mm
weight23.000 kg
Availabilityon demand
1795100000 100
PN16 bar
L350 mm
weight32.000 kg
Availabilityon demand
1795125000 125
PN16 bar
L400 mm
weight48.000 kg
Availabilityon demand
1795150000 150
PN16 bar
L480 mm
weight76.000 kg
Availabilityon demand
1795200000 200
PN10 bar
L600 mm
weight118.000 kg
Availabilityon demand
1795200016 200
PN16 bar
L600 mm
weight105.000 kg
Availabilityon demand
1795250000 250
PN10/16 bar
L730 mm
weight243.000 kg
Availabilityon demand
1795300000 300
PN10/16 bar
L850 mm
weight354.000 kg
Availabilityon demand

Physical characteristics

  • The main valve is a hydraulically operating diaphragm valve. The work energy is the inherent medium.
  • Most valve types operate purely hydraulically without any foreign energy.

Application

  • To use in drinking water systems (other media after consultation)
  • Slow, step–by–step opening or closing of a supply system by means of electrical impulses
  • Regulation of water levels in the reservoir (regulation of the inflow or outflow in the reservoir)
  • Regulation of the flow rates
  • Regulation of the flow rates for cooling circuits (in conjunction with a temperature switch)

Mode of operation

  • The open/close valve for the electric actuation opens or closes step–by–step depending on the respective actuation of the solenoid valve. The valve closes when the solenoid valves are de–energised. The opening and closing speeds can be set on the throttle non–return valve.

Product information

  • To calculate the dimensions of the valve please refer to the following information:
  • Maximum and minimum inlet pressure (static and dynamic pressure ratios)
  • Existing counterpressure
  • Required flow rate
  • Maximum permissible loss of pressure
  • Voltage information for the solenoid valve
  • Available line diameters and lengths
  • Construction of the valve (straight or angle design)
  • For the calculation basis, information on the loss of pressure and the characteristic values of the valve, please refer to the end of Chapter E.

Design

  • Design according to DIN EN 1074
  • Construction length acc. to DIN EN 558
  • Flange mass according to DIN 1092-2, to PN 25 DN 300
  • Pressure levels: PN 10 or PN 16 to DN 300, PN 25 to DN 200, higher pressures on request.
  • Nominal widths DN 50, DN 80, DN 100 and DN 150 available in angular design
  • Nominal widths 1 ½" and 2" with threaded connection (female thread)
  • Medium temperature up to 40°C

Installation and assembly

  • Shut–off valves should be fitted on both sides of the valve and a dirt trap should be installed on the inlet side of the valve. Depending on the installation situation, a mounting/dismounting adapter should be provided.

Vantages

  • Maintenance-free, non-rusting valve seat
  • Pressed-in seat
  • EWS-coating according to RAL GSK