On/Off valve for electrical control - closes without currentOn/Off valve for electrical control - closes without current

1603 On/Off valve for electrical control - closes without current

Article No. DNPN
(bar)
L
(mm)
weight
(kg)
Availability watchlist
1603007000 1 1/2" 16 210 9.000 on demand
1603008000 2" 16 210 10.000 on demand
1603040000 40 16 200 15.000 on demand
1603050000 50 16 230 17.800 on demand
1603065000 65 16 290 23.000 on demand
1603080000 80 16 310 26.600 on demand
1603100000 100 16 350 37.000 on demand
1603125000 125 16 400 53.000 on demand
1603150000 150 16 480 76.000 on demand
1603200000 200 10 600 116.100 on demand
1603200016 200 16 600 118.000 on demand
1603250000 250 10/16 730 249.000 on demand
1603300000 300 10/16 850 356.000 on demand
DN
watchlist
1603007000 1 1/2"
PN16 bar
L210 mm
weight9.000 kg
Availabilityon demand
1603008000 2"
PN16 bar
L210 mm
weight10.000 kg
Availabilityon demand
1603040000 40
PN16 bar
L200 mm
weight15.000 kg
Availabilityon demand
1603050000 50
PN16 bar
L230 mm
weight17.800 kg
Availabilityon demand
1603065000 65
PN16 bar
L290 mm
weight23.000 kg
Availabilityon demand
1603080000 80
PN16 bar
L310 mm
weight26.600 kg
Availabilityon demand
1603100000 100
PN16 bar
L350 mm
weight37.000 kg
Availabilityon demand
1603125000 125
PN16 bar
L400 mm
weight53.000 kg
Availabilityon demand
1603150000 150
PN16 bar
L480 mm
weight76.000 kg
Availabilityon demand
1603200000 200
PN10 bar
L600 mm
weight116.100 kg
Availabilityon demand
1603200016 200
PN16 bar
L600 mm
weight118.000 kg
Availabilityon demand
1603250000 250
PN10/16 bar
L730 mm
weight249.000 kg
Availabilityon demand
1603300000 300
PN10/16 bar
L850 mm
weight356.000 kg
Availabilityon demand
  • Comment: Up to DN 100 as per the diagram. From DN 125 with orifice plate and 2/2-way solenoid valve.

Physical characteristics

  • The main valve is a hydraulically operating diaphragm valve. The work energy is the inherent medium.
  • Most valve types operate purely hydraulically without any foreign energy.

Application

  • To use in drinking water systems (other media after consultation)
  • Level control in a reservoir or pressure–breaking shaft
  • Level control in an equalising basin

Mode of operation

  • The open/close valve with an electric level switch, opens or closes for the electric actuation via the level switch and the solenoid valve The valve is closed when it is de–energised. The closing speed can be adjusted by means of a throttle non–return valve to prevent surges in pressure.

Product information

  • To calculate the dimensions of the valve please refer to the following information:
  • Maximum and minimum inlet pressure (static and dynamic pressure ratios)
  • Existing counterpressure of the reservoir
  • Required flow rate
  • Voltage information for the solenoid valve
  • Available line diameters and lengths
  • Construction of the valve (straight or angle design)
  • The level switch operates with 24 VDC. The supply voltage for the control is 230 VAC.
  • For the calculation basis, information on the loss of pressure and the characteristic values of the valve, please refer to the end of Chapter E.

Design

  • Design according to DIN EN 1074
  • Construction length acc. to DIN EN 558
  • Flange mass according to DIN 1092-2, to PN 25 DN 300
  • Pressure levels: PN 10 or PN 16 to DN 300, PN 25 to DN 200, higher pressures on request.
  • Nominal widths DN 50, DN 80, DN 100 and DN 150 available in angular design
  • Nominal widths 1 ½" and 2" with threaded connection (female thread)
  • Medium temperature up to 40°C

Installation and assembly

  • Shut–off valves should be fitted on both sides of the valve and a dirt trap should be installed on the inlet side of the valve. Depending on the installation situation, a mounting/dismounting adapter should be provided. If there is a free run into the water tank downstream from the valve, the slider on the outlet side can be omitted. Depending on the pressure ratios, an orifice plate should be installed on the outlet side of the valve and an opening limiter on the valve. The installation of a float protection pipe is recommended to guide the float.

Vantages

  • Maintenance-free, non-rusting valve seat
  • Pressed-in seat
  • EWS-coating according to RAL GSK
more