Limitation valve MBV with pressure reductionLimitation valve MBV with pressure reduction

1302 Limitation valve MBV with pressure reduction

Article No. DNPN
(bar)
L
(mm)
weight
(kg)
Availability watchlist
1302007000 1 1/2" 16 210 11.000 on demand
1302008000 2" 16 210 11.000 on demand
1302040000 40 16 200 15.750 on demand
1302050000 50 16 230 16.250 on demand
1302065000 65 16 290 21.300 on demand
1302080000 80 16 310 27.400 on demand
1302080025 80 25 310 27.400 on demand
1302100000 100 16 350 35.400 on demand
1302125000 125 16 400 51.500 on demand
1302150000 150 16 480 76.000 on demand
1302200000 200 10 600 114.600 on demand
1302200016 200 16 600 114.600 on demand
1302250000 250 10/16 730 247.000 on demand
1302300000 300 10/16 850 358.000 on demand
DN
watchlist
1302007000 1 1/2"
PN16 bar
L210 mm
weight11.000 kg
Availabilityon demand
1302008000 2"
PN16 bar
L210 mm
weight11.000 kg
Availabilityon demand
1302040000 40
PN16 bar
L200 mm
weight15.750 kg
Availabilityon demand
1302050000 50
PN16 bar
L230 mm
weight16.250 kg
Availabilityon demand
1302065000 65
PN16 bar
L290 mm
weight21.300 kg
Availabilityon demand
1302080000 80
PN16 bar
L310 mm
weight27.400 kg
Availabilityon demand
1302080025 80
PN25 bar
L310 mm
weight27.400 kg
Availabilityon demand
1302100000 100
PN16 bar
L350 mm
weight35.400 kg
Availabilityon demand
1302125000 125
PN16 bar
L400 mm
weight51.500 kg
Availabilityon demand
1302150000 150
PN16 bar
L480 mm
weight76.000 kg
Availabilityon demand
1302200000 200
PN10 bar
L600 mm
weight114.600 kg
Availabilityon demand
1302200016 200
PN16 bar
L600 mm
weight114.600 kg
Availabilityon demand
1302250000 250
PN10/16 bar
L730 mm
weight247.000 kg
Availabilityon demand
1302300000 300
PN10/16 bar
L850 mm
weight358.000 kg
Availabilityon demand

Physical characteristics

  • The main valve is a hydraulically operating diaphragm valve. The work energy is the inherent medium.
  • Most valve types operate purely hydraulically without any foreign energy.

Application

  • To use in drinking water systems (other media after consultation)
  • Limitation of the inflow from a pressure zone into a lower pressure zone
  • Constantly maintaining a filter flow
  • The supply to a secondary network necessitates a limitation of the flow, so as to not endanger, for example, the extinguishing reservoir of the primary network (in combination with a reduction in pressure).

Mode of operation

  • The flow–control valve completely hydraulically ensures a pre–determined maximum flow, irrespective of any changes in the operating pressure. The nominal flow rate can be progressively varied up to ±15% via the control valve. The inlet pressure is reduced to a constant outlet pressure downstream of the orifice plate.

Product information

  • To calculate the dimensions of the valve please refer to the following information:
  • Maximum and minimum inlet pressure (static and dynamic pressure ratios)
  • Required outlet pressure after the orifice plate
  • Required flow rate
  • Permissible loss of pressure incl. measuring orifice (usually 0.5 bar over the valve and orifice plate)
  • Available line diameters and lengths
  • Construction of the valve (straight or angle design)
  • For the calculation basis, information on the loss of pressure and the characteristic values of the valve, please refer to the end of Chapter E.

Design

  • Design according to DIN EN 1074
  • Construction length acc. to DIN EN 558
  • Flange mass according to DIN 1092-2, to PN 25 DN 300
  • Pressure levels: PN 10 or PN 16 to DN 300, PN 25 to DN 200, higher pressures on request.
  • Nominal widths DN 50, DN 80, DN 100 and DN 150 available in angular design
  • Nominal widths 1 ½" and 2" with threaded connection (female thread)
  • Medium temperature up to 40°C

Installation and assembly

  • Shut–off valves should be fitted on both sides of the valve and a dirt trap should be installed on the inlet side of the valve. Depending on the installation situation, a mounting/dismounting adapter and an aeration and ventilation system should be provided.
  • The orifice plate must be installed after the valve. It is recommended that the following measurements are taken into consideration:
  • X = 5 x DN, distance between the valve and the orifice plate in a straight line
  • Y = 3 x DN, distance after the orifice plate and the shut–off component, in a straight line

Vantages

  • Maintenance-free, non-rusting valve seat
  • Pressed-in seat
  • EWS-coating according to RAL GSK