Pressure retention valve DAV for monitoring third-party pressurePressure retention valve DAV for monitoring third-party pressure

1405 Pressure retention valve DAV for monitoring third-party pressure

Article No. DNPN
(bar)
L
(mm)
weight
(kg)
Availability watchlist
1405007000 1 1/2" 16 210 11.000 on demand
1405008000 2" 16 210 11.000 on demand
1405040000 40 16 200 15.750 on demand
1405050000 50 16 230 16.250 on demand
1405065000 65 16 290 21.300 on demand
1405080000 80 16 310 27.400 on demand
1405100000 100 16 350 35.400 on demand
1405125000 125 16 400 51.500 on demand
1405150000 150 16 480 76.000 on demand
1405200000 200 10 600 114.600 on demand
1405200016 200 16 600 114.600 on demand
1405250000 250 10/16 730 247.000 on demand
1405300000 300 10/16 850 359.000 on demand
DN
watchlist
1405007000 1 1/2"
PN16 bar
L210 mm
weight11.000 kg
Availabilityon demand
1405008000 2"
PN16 bar
L210 mm
weight11.000 kg
Availabilityon demand
1405040000 40
PN16 bar
L200 mm
weight15.750 kg
Availabilityon demand
1405050000 50
PN16 bar
L230 mm
weight16.250 kg
Availabilityon demand
1405065000 65
PN16 bar
L290 mm
weight21.300 kg
Availabilityon demand
1405080000 80
PN16 bar
L310 mm
weight27.400 kg
Availabilityon demand
1405100000 100
PN16 bar
L350 mm
weight35.400 kg
Availabilityon demand
1405125000 125
PN16 bar
L400 mm
weight51.500 kg
Availabilityon demand
1405150000 150
PN16 bar
L480 mm
weight76.000 kg
Availabilityon demand
1405200000 200
PN10 bar
L600 mm
weight114.600 kg
Availabilityon demand
1405200016 200
PN16 bar
L600 mm
weight114.600 kg
Availabilityon demand
1405250000 250
PN10/16 bar
L730 mm
weight247.000 kg
Availabilityon demand
1405300000 300
PN10/16 bar
L850 mm
weight359.000 kg
Availabilityon demand

Physical characteristics

  • The main valve is a hydraulically operating diaphragm valve. The work energy is the inherent medium.
  • Most valve types operate purely hydraulically without any foreign energy.

Application

  • To use in drinking water systems (other media after consultation)
  • As an open/shut valve with hydraulic control (e.g. sprinkler systems)
  • Maintaining a network pressure

Mode of operation

  • The pressure–sustaining valve opens quickly via the control line of the external pressure and closes slowly when the external pressure lowers. So that the control valve can be relieved again after pressurisation (and the main valve closes again), it must be possible to relieve the control line of the external pressure. The pressure of the control line (external pressure) should be within the range of 2 to 16 bar.

Product information

  • To calculate the dimensions of the valve please refer to the following information:
  • Maximum and minimum inlet pressure (static and dynamic pressure ratios)
  • Desired maximum loss of pressure
  • Level of the external pressure
  • Maximum and minimum flow rates
  • Available line diameters and lengths
  • Construction of the valve (straight or angle design)
  • For the calculation basis, information on the loss of pressure and the characteristic values of the valve, please refer to the end of Chapter E.

Design

  • Design according to DIN EN 1074
  • Construction length acc. to DIN EN 558
  • Flange mass according to DIN 1092-2, to PN 25 DN 300
  • Pressure levels: PN 10 or PN 16 to DN 300, PN 25 to DN 200, higher pressures on request.
  • Nominal widths DN 50, DN 80, DN 100 and DN 150 available in angular design
  • Nominal widths 1 ½" and 2" with threaded connection (female thread)
  • Medium temperature up to 40°C

Installation and assembly

  • Shut–off valves should be fitted on both sides of the valve and a dirt trap should be installed on the inlet side of the valve. Depending on the installation situation, a mounting/dismounting adapter should be provided.

Vantages

  • Maintenance-free, non-rusting valve seat
  • Pressed-in seat
  • EWS-coating according to RAL GSK
more