Pressure reducing valve for 2 pressure zonesPressure reducing valve for 2 pressure zones

1593 Pressure reducing valve for 2 pressure zones

Article No. DNPN
(bar)
L
(mm)
weight
(kg)
Availability watchlist
1593007000 1 1/2" 16 210 10.000 on demand
1593008000 2" 16 210 10.000 on demand
1593040000 40 16 200 13.000 on demand
1593050000 50 16 230 17.000 on demand
1593065000 65 16 290 21.000 on demand
1593080000 80 16 310 26.000 on demand
1593100000 100 16 350 35.400 on demand
1593100025 100 25 350 35.400 on demand
1593125000 125 16 400 51.550 on demand
1593150000 150 16 480 76.000 on demand
1593200000 200 10 600 116.150 on demand
1593200016 200 16 600 116.150 on demand
1593250000 250 10/16 730 247.000 on demand
1593300000 300 10/16 850 360.500 on demand
DN
watchlist
1593007000 1 1/2"
PN16 bar
L210 mm
weight10.000 kg
Availabilityon demand
1593008000 2"
PN16 bar
L210 mm
weight10.000 kg
Availabilityon demand
1593040000 40
PN16 bar
L200 mm
weight13.000 kg
Availabilityon demand
1593050000 50
PN16 bar
L230 mm
weight17.000 kg
Availabilityon demand
1593065000 65
PN16 bar
L290 mm
weight21.000 kg
Availabilityon demand
1593080000 80
PN16 bar
L310 mm
weight26.000 kg
Availabilityon demand
1593100000 100
PN16 bar
L350 mm
weight35.400 kg
Availabilityon demand
1593100025 100
PN25 bar
L350 mm
weight35.400 kg
Availabilityon demand
1593125000 125
PN16 bar
L400 mm
weight51.550 kg
Availabilityon demand
1593150000 150
PN16 bar
L480 mm
weight76.000 kg
Availabilityon demand
1593200000 200
PN10 bar
L600 mm
weight116.150 kg
Availabilityon demand
1593200016 200
PN16 bar
L600 mm
weight116.150 kg
Availabilityon demand
1593250000 250
PN10/16 bar
L730 mm
weight247.000 kg
Availabilityon demand
1593300000 300
PN10/16 bar
L850 mm
weight360.500 kg
Availabilityon demand

Physical characteristics

  • The main valve is a hydraulically operating diaphragm valve. The work energy is the inherent medium.
  • Most valve types operate purely hydraulically without any foreign energy.

Application

  • To use in drinking water systems (other media after consultation)
  • Increase in pressure in the network in the event of a fire (actuation via the fire department station)
  • Setting of the day and night operation of the network pressures (daytime operation for higher pressure, night time operation for lower network pressure)

Mode of operation

  • The pressure reducing valve, type 1593, works in 2 operating stages:
  • Operating stage a: In a normal operation, a variable inlet pressure (p1) is reduced to a constant outlet pressure (p2) by means of a control valve. Example: p1 = 12 bar / p2 = 8 bar.
  • Operating stage b: This second stage can be put into operation by means of the solenoid valve and the second control valve. For example: p1 = 12 bar / p2 = 10 bar.
  • Fluctuating flow rate and inlet pressure (p1) have no effect on the controlled outlet pressure (p2). The outlet pressure is adjustable in the range from 1.5 to 12 bar (standard design).

Product information

  • To calculate the dimensions of the valve please refer to the following information:
  • Maximum and minimum inlet pressure (static and dynamic pressure ratios)
  • Required outlet pressure
  • Voltage information for the solenoid valve
  • Maximum and minimum flow rates
  • Possible requirement for extinguishing water
  • Available line diameters and lengths
  • Construction of the valve (straight or angle design)
  • For the calculation basis, information on the loss of pressure and the characteristic values of the valve, please refer to the end of Chapter E.

Design

  • Design according to DIN EN 1074
  • Construction length acc. to DIN EN 558
  • Flange mass according to DIN 1092-2, to PN 25 DN 300
  • Pressure levels: PN 10 or PN 16 to DN 300, PN 25 to DN 200, higher pressures on request.
  • Nominal widths DN 50, DN 80, DN 100 and DN 150 available in angular design
  • Nominal widths 1 ½" and 2" with threaded connection (female thread)
  • Medium temperature up to 40°C

Installation and assembly

  • Shut–off valves should be fitted on both sides of the valve and a dirt trap should be installed on the inlet side of the valve. Depending on the installation situation, a mounting/dismounting adapter and an aeration and ventilation system should be provided.

Vantages

  • Maintenance-free, non-rusting valve seat
  • Pressed-in seat
  • EWS-coating according to RAL GSK
more