Pressure reducing valve with motor-controlled pilot valvePressure reducing valve with motor-controlled pilot valve

1515 Pressure reducing valve with motor-controlled pilot valve

Article No. DNPN
(bar)
L
(mm)
weight
(kg)
Availability watchlist
1515040000 40 10/16 200 17.000 on demand
1515050000 50 10/16 230 17.500 on demand
1515065000 65 10/16 290 22.600 on demand
1515080000 80 10/16 310 28.600 on demand
1515100000 100 10/16 350 36.600 on demand
1515125000 125 10/16 400 52.600 on demand
1515151000 150 10/16 480 76.000 on demand
1515200010 200 10 600 115.700 on demand
1515200016 200 16 600 115.700 on demand
1515250000 250 10/16 730 249.000 on demand
1515300010 300 10/16 850 360.000 on demand
DN
watchlist
1515040000 40
PN10/16 bar
L200 mm
weight17.000 kg
Availabilityon demand
1515050000 50
PN10/16 bar
L230 mm
weight17.500 kg
Availabilityon demand
1515065000 65
PN10/16 bar
L290 mm
weight22.600 kg
Availabilityon demand
1515080000 80
PN10/16 bar
L310 mm
weight28.600 kg
Availabilityon demand
1515100000 100
PN10/16 bar
L350 mm
weight36.600 kg
Availabilityon demand
1515125000 125
PN10/16 bar
L400 mm
weight52.600 kg
Availabilityon demand
1515151000 150
PN10/16 bar
L480 mm
weight76.000 kg
Availabilityon demand
1515200010 200
PN10 bar
L600 mm
weight115.700 kg
Availabilityon demand
1515200016 200
PN16 bar
L600 mm
weight115.700 kg
Availabilityon demand
1515250000 250
PN10/16 bar
L730 mm
weight249.000 kg
Availabilityon demand
1515300010 300
PN10/16 bar
L850 mm
weight360.000 kg
Availabilityon demand

Physical characteristics

  • The main valve is a hydraulically operating diaphragm valve. The work energy is the inherent medium.
  • Most valve types operate purely hydraulically without any foreign energy.

Application

  • In combination with a PLC controller, different time–dependent target pressure values, for example, can be set This application can be used for lowering the pressure during the night or for setting up a higher extinguishing pressure.

Mode of operation

  • The pressure reducing valve with motor–driven pilot valve reduces a variable inlet pressure (p1) to a constant lower outlet pressure (P2). Fluctuating flow rate and inlet pressure have no effect on the outlet pressure controlled by the control valve. The outlet pressure (p2) is adjustable in the range from 1.5 to 12 bar.

Product information

  • To calculate the dimensions of the valve please refer to the following information:
  • Maximum and minimum inlet pressure (static and dynamic pressure ratios)
  • Pressure levels and time zones
  • Desired outlet pressure
  • Maximum and minimum flow rates
  • Possible requirement for extinguishing water
  • Available line diameters and lengths
  • Construction of the valve (straight or angle design)
  • For the calculation basis, information on the loss of pressure and the characteristic values of the valve, please refer to the end of Chapter E.

Design

  • Design according to DIN EN 1074
  • Construction length acc. to DIN EN 558
  • Flange mass according to DIN 1092-2, to PN 25 DN 300
  • Druckstufen: PN 10 oder PN 16 bis DN 300; PN 25 bis DN 200
  • Nominal widths DN 50, DN 80, DN 100 and DN 150 available in angular design
  • Nominal widths 1 ½" and 2" with threaded connection (female thread)
  • Medium temperature up to 40°C

Installation and assembly

  • Shut–off valves should be fitted on both sides of the valve and a dirt trap should be installed on the inlet side of the valve. Depending on the installation situation, a mounting/dismounting adapter and an aeration and ventilation system should be provided.

Vantages

  • Maintenance-free, non-rusting valve seat
  • Pressed-in seat
  • Counter-seat with optimised geometry
  • EWS coating according to RAL GSK (coating thickness: min. 250 µm)
  • Optical position indicator in stainless steel, including vent screw built onto the valves as standard (except Open/Close and float valves).
  • Control line: Fittings and piping in stainless steel.
  • Control line: Connection with the clamping ring can be dismounted radially. No protruding pipe end after the clamping ring.
  • The necessary shut-off elements are available in the control line as standard. The ball valves are made from stainless steel and have a short handle. No long actuating lever.
  • The necessary pressure gauge is built in as standard, and can always be shut off with a ball valve (replacement of the pressure gauge possible without having to shut down the system).
  • Dirt trap in the control line installed horizontally for flawless functioning and cleaning. The dirt does not fall back when cleaning the filter screen.
  • Pilot valve manually adjustable without requiring a tool.
  • DVGW and SVGW approvals