Flow limition valve MBV with electrical remote control - open without currentFlow limition valve MBV with electrical remote control - open without currentFlow limition valve MBV with electrical remote control - open without currentFlow limition valve MBV with electrical remote control - open without current

1304 Flow limition valve MBV with electrical remote control - open without current

Article No. DNPN
(bar)
L
(mm)
weight
(kg)
Availability watchlist
1304007000 1 1/2" 16 210 11.000 on demand
1304008000 2" 16 210 11.100 on demand
1304040000 40 16 200 15.750 on demand
1304050000 50 16 230 16.250 on demand
1304065000 65 16 290 21.300 on demand
1304080000 80 16 310 27.400 on demand
1304100000 100 16 350 35.400 on demand
1304125000 125 16 400 51.500 on demand
1304150000 150 16 480 76.000 on demand
1304200000 200 10 600 114.600 on demand
1304200016 200 16 600 114.600 on demand
1304250000 250 10/16 730 247.000 on demand
1304300000 300 10/16 850 358.000 on demand
DN
watchlist
1304007000 1 1/2"
PN16 bar
L210 mm
weight11.000 kg
Availabilityon demand
1304008000 2"
PN16 bar
L210 mm
weight11.100 kg
Availabilityon demand
1304040000 40
PN16 bar
L200 mm
weight15.750 kg
Availabilityon demand
1304050000 50
PN16 bar
L230 mm
weight16.250 kg
Availabilityon demand
1304065000 65
PN16 bar
L290 mm
weight21.300 kg
Availabilityon demand
1304080000 80
PN16 bar
L310 mm
weight27.400 kg
Availabilityon demand
1304100000 100
PN16 bar
L350 mm
weight35.400 kg
Availabilityon demand
1304125000 125
PN16 bar
L400 mm
weight51.500 kg
Availabilityon demand
1304150000 150
PN16 bar
L480 mm
weight76.000 kg
Availabilityon demand
1304200000 200
PN10 bar
L600 mm
weight114.600 kg
Availabilityon demand
1304200016 200
PN16 bar
L600 mm
weight114.600 kg
Availabilityon demand
1304250000 250
PN10/16 bar
L730 mm
weight247.000 kg
Availabilityon demand
1304300000 300
PN10/16 bar
L850 mm
weight358.000 kg
Availabilityon demand

Physical characteristics

  • The main valve is a hydraulically operating diaphragm valve. The work energy is the inherent medium.
  • Most valve types operate purely hydraulically without any foreign energy.

Application

  • To use in drinking water systems (other media after consultation)
  • Limitation of the inflow from a pressure zone into a lower pressure zone
  • Constantly maintaining a filter flow
  • The supply to a secondary network necessitates a limitation of the flow, so as to not endanger, for example, the extinguishing reservoir of the primary network (in combination with a reduction in pressure).
more