System Separator Type 754 BA Thread PN 10System Separator Type 754 BA Thread PN 10

7574 System Separator Type 754 BA Thread PN 10

Article No. DNPN
(bar)
H2Hø DLø BL1weight
(kg)
Availability watchlist
7574020000 1/2" 10 44.5 263 40-60 227 102 152.5 2.900 on demand
7574025000 3/4" 10 44.5 263 40-60 227 102 152.5 2.900 on demand
7574032000 1" 10 72.5 292 40-60 280 90 186.5 4.700 on demand
7574040000 1 1/4" 10 72.5 292 40-60 280 90 186.5 4.700 on demand
7574050000 1 1/2" 10 103.5 382 50 387 169 274 11.300 on demand
7574063000 2" 10 103.5 382 50 395 169 274 11.400 on demand
DN
watchlist
7574020000 1/2"
PN10 bar
H244.5
H263
ø D40-60
L227
ø B102
L1152.5
weight2.900 kg
Availabilityon demand
7574025000 3/4"
PN10 bar
H244.5
H263
ø D40-60
L227
ø B102
L1152.5
weight2.900 kg
Availabilityon demand
7574032000 1"
PN10 bar
H272.5
H292
ø D40-60
L280
ø B90
L1186.5
weight4.700 kg
Availabilityon demand
7574040000 1 1/4"
PN10 bar
H272.5
H292
ø D40-60
L280
ø B90
L1186.5
weight4.700 kg
Availabilityon demand
7574050000 1 1/2"
PN10 bar
H2103.5
H382
ø D50
L387
ø B169
L1274
weight11.300 kg
Availabilityon demand
7574063000 2"
PN10 bar
H2103.5
H382
ø D50
L395
ø B169
L1274
weight11.400 kg
Availabilityon demand

Application

  • System separator with controllable differential pressure, Type BA
  • Separation of drinking water in systems such as chemical plants, car wash facilities, disinfection systems, emergency cooling, irrigation systems, or entire drinking water systems.

Mode of operation

  • The system separator consists of three chambers, where the differential pressure in the flow direction from the first to the third chamber must be at least 140 mbar higher. If this value falls below the minimum, the discharge valve opens, and the water flows into the sewage system instead of back into the drinking water network.

Design

  • Execution according to EN 1717 and EN 12729
  • Pressure: PN 10
  • Pipe fitting with external thread 1/2" to 2"
  • Minimum flow pressure: 2 bar, maximum flow velocity: 3.0 m/s, operating pressure: max. 10 bar
  • Medium temperature up to 65°C

Installation and assembly

  • Both sides of the valve must have shut-off valves installed, and a strainer must be mounted on the valve inlet side.
  • The installation must be horizontal and should be carried out after the water meter.
  • The sewer connection must be large enough so that the valve never comes into contact with water, even in the event of flooding.
  • System separators of type 574 BA are maintenance-required according to SVGW W3/E2.